  The operator has various options for achieving the desired pressure. The user can perform tests at pressures up to 900 psi (6205 kPa) with the compact, easily attached carbon dioxide pressuring unit that is provided. Or the user can perform tests at pressures up to 1200 psi (8274 kPa) on the cell and 750 psi (5171 kPa) on the backpressure receiver when using the nitrogen manifold along with the nitrogen regulator assembly. The nitrogen manifolds have built-in safety relief valves that are set at 1200 psi (8274 kPa) for the cell and 750 psi (5171 kPa) for the backpressure receivers.

  操作者有多种选择来达到预期的压力。用户可以在压力高达9000psi (6205 kPa)的情况下进行测试。或者,当用户使用氮气歧管和氮气调节器总成时,可以在电池上的压力达到1200 psi (8274 kPa),在背压接收器上的压力达到750 psi (5171 kPa)的情况下进行测试。氮气歧管内置安全阀,电池的安全阀压力为1200 psi (8274 kPa),反压力接收器的安全阀压力为750 psi (5171 kPa)。

  All HPHT filter presses should be pressurized with either nitrogen or carbon dioxide. Self-contained and convenient carbon dioxide capsules are used with the 175 ml cells and the 15 ml backpressure receivers as shown in Figures 3-1 and 3-3. The carbon dioxide capsules have a maximum pressure of approximately 900 psi (6205 kPa). If the test requires a higher pressure, then use one of the three available nitrogen pressurization systems.

  82839536 比重计 OFI 115-00

  83107124 加热套 Fann 206966

  82651450 500ml高温高压失水仪样品杯 Fann 209570

  82651457 175ml高温高压失水仪样品杯 Fann 209569

  83107123 175ml高温高压失水仪加热套 Fann 209506

  83107123 500ml高温高压失水仪加热套 Fann 209541

  81972339 滚子炉老化罐 OFI 175-50

  81490030 老化罐杯体内聚四氟O型圈 OFI 175-09-1

  81490030 老化罐杯体外部O型圈 OFI 175-46

  81972341 直径3/8英寸固定螺钉 OFI 175-14

  81972340 阀杆 OFI 175-16

  所有高压压滤机都应该用氮气或二氧化碳加压。175ml的电池和15ml的背压接收器采用立方便的二氧化碳胶囊,如图3-1和3-3所示。这种二氧化碳胶囊的大压力约为900 psi (6205 kPa)。如果测试要求更高的压力,那么使用三个可用的氮气加压系统之一。

  Nitrogen pressurization is usually preferred for use with the 500 ml cells because this cell requires a greater volume of gas. Three nitrogen systems are available:1) single nitrogen manifold; 2) dual nitrogen manifold; 3) HP primary and LP secondary HPHT manifold. The single nitrogen manifold, shown in Figure 3-4, supplies pressure to the cell only, and backpressure is optional. The backpressure receiver requires carbon dioxide. The dual nitrogen manifold, shown in Figure 3-5, is usually furnished and has capacity to supply maximum pressures of 1200 psi (8274 kPa) to the cell and 750 psi (5171 kPa) to the backpressure receiver. The HP primary and LP secondary HPHT manifold, shown in Figure 3-6, allows pressurization of the cell to 1200 psi (8274 kPa), but supplies a lower backpressure of 170 psi (1172 kPa) maximum.

  氮加压通常是的使用与500毫升细胞,因为这个细胞需要更大的体积的气体。现有三种氮气系统:1)单氮气歧管;2)双氮气歧管;3) HP主副HPHT歧管。如图3-4所示,单氮气歧管仅向电池提供压力,反压力是可选的。反压力接收器需要二氧化碳。如图3-5所示的双氮气歧管通常配置,能够向电池提供大压力1200 psi (8274 kPa),向背压接收器提供大压力750 psi (5171 kPa)。如图3-6所示,高压一次和低压二次HPHT歧管可以使电池增压到1200 psi (8274 kPa),但是大反压力为170 psi (1172 kPa)。

  For temperatures greater than 200°F (93°C), a backpressure receiver must be used to prevent boiling of the filtrate. The standard backpressure receiver has a separate carbon dioxide pressuring source to provide the standard 100 psi (689 kPa) backpressure. Larger volume and/or higher backpressure receivers also may be used. These are connected to the nitrogen manifold allowing for pressurizing up to 750 psi (5171 kPa) backpressure. (If an ion analysis of the filtrate is required, nitrogen should be used for the backpressure.)

  温度大于200°F (93°C),用于防止反压力接收机滤液的沸腾。标准背压接收器有一个单的二氧化碳加压源,提供标准100 psi (689 kPa)背压。也可以使用体积更大和/或背压更高的接收器。这些都连接到氮气歧管,允许增压高达750 psi (5171 kPa)的反压力。(如果需要对滤液进行离子分析,则应使用氮气进行反压。)

  A backpressure receiver of 15 ml capacity is normally used with the 175 ml cells. See Figures 3-1, 3-7 and 3-8. Either carbon dioxide or nitrogen can be used as the pressurizing medium. These 15 ml backpressure receivers also may be connected to the 500 ml cells when a small receiver volume is desired. However, the 500 ml cells are usually connected to the 100 ml capacity backpressure receiver shown in Figure 3-9. The nitrogen pressurized backpressure receivers can handle a maximum pressure of 750 psi (5171 kPa).

  一个容量为15毫升的背压接收器通常与175毫升的电池一起使用。参见图3-1、3-7和3-8。无论是二氧化碳还是氮气都可以用作加压介质。当需要小容量的接收器时,也可以将这些15毫升的背压接收器连接到500毫升的电池上。然而,500ml的电池通常连接到100ml容量的背压接收器,如图3-9所示。氮气加压背压接收器的大压力可达750 psi (5171 kPa)。

  To achieve the desired temperature, use the thermostat knob that is located on the heating jacket. To measure the actual temperature of the heating jacket and cell, insert a stem thermometer into the thermometer well in the heating jacket or the cell. The thermostat knob has a scale of from 1 to 10; take note of the scale number and the actual measured temperature for future reference. See Figures 3-1 and 3-2 for pictures of the heating jackets, both 175 ml and 500 ml.Caps with the CellTell? Positive Pressure Indicator are only used on the top of the double opening cells. The other end cap types can be used with the 175 ml or 500 ml cells and the single or double opening cells. Several screen mesh selections are available for use with the end cap for the removable screen assembly. These screens are listed in Section 8.

  要达到所需的温度,请使用位于加热套上的温控器旋钮。要测量加热夹套和电池的实际温度,请在加热夹套或电池的温度计孔中插入一个干式温度计。恒温旋钮的刻度从1到10;注意刻度和实际测量温度,以备将来参考。见图3 - 1和3 - 2加热夹克的照片,175毫升和500 ml.Caps CellTell?积极压力指示器只用于双开顶部的细胞。另一种端帽类型可与175毫升或500毫升的细胞和单开或双开的细胞一起使用。可拆卸屏幕组件的端盖上有几个筛网可供选择。这些屏幕列在第8节中。

  Double-ended cell bodies are available for use with ceramic disc filters, where one end is used for the ceramic filter disc. The opposite end is standard and can accept either end cap. The ceramic filter disc end requires a ceramic filter disc cap. To use these cells and caps for ceramic filter discs with any of the standard filter paper and support screen assemblies, an adapter ring and O-ring must be assembled into the cell. See Table 8-1 Accessories for a list of ceramic disc filters that are available for separate purchase. Refer to Section 9.6 Cell Assemblies for cell drawings, descriptions, and part numbers.

  双端胞体可与陶瓷圆盘过滤器配套使用,其中一端用于陶瓷圆盘过滤器。另一端是标准的,可以接受帽。陶瓷过滤盘结束需要陶瓷过滤圆盘帽。使用这些细胞和帽与任何标准的陶瓷过滤器光盘滤纸和支持屏幕组件,一个适配器组装成细胞环和o形环。可单购买的陶瓷圆盘过滤器的清单见表8-1附件。有关单元图、说明和部件编号,请参阅第9.6节单元组件。美国Fann 209541 500ml高温高压失水仪加热套HPHT压滤机配件